Black Box CLM5000 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Testeurs de réseaux câblés Black Box CLM5000. Black Box CLM5000 cable network tester Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
BL A C K B O X
®
Use to measure cable length and generate tone
on industrial, telco, and coax cable (not CATx).
Works on single- or two-conductor cables.
Compact, handheld unit.
Cable Length Meter
December 2009
CLM5000
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call
724-746-5500) • FREE technical support 24 hours a day, 7 days a
week: Call 724-746-5500 or fax 724-746-0746 • Mailing address:
Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 •
Web site: www.blackbox.com • E-mail: [email protected]
Customer
Support
Information
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - BL A C K B O X

BL A C K B O X® Use to measure cable length and generate tone on industrial, telco, and coax cable (not CATx). Works on single- or two-conductor

Page 2

724-746-5500 | blackbox.com Cable Length MeterPage 82. Overview2.1 IntroductionThe Cable Length Meter for industrial, network, telco, and coax cab

Page 3 - FCC and IC RFI Statements

724-746-5500 | blackbox.com Chapter 2: OverviewPage 92.3 What’s Included• (1) Cable Length Meter• (1) double-banana to BNC + BNC F to F jack• (2)

Page 4

724-746-5500 | blackbox.com Cable Length MeterPage 103. General Functions3.1 PWR Key and Auto Power OffPress the PWR key to turn the unit on and o

Page 5 - NOM Statement

724-746-5500 | blackbox.com Chapter 3: General FunctionsPage 113.4 LCD Display IconsTable 3-1 describes the icons that appear on the LCD display.T

Page 6

724-746-5500 | blackbox.com Page 12Cable Length Meter4. Using the Cable Length Meter4.1 AWG Mode This mode allows length measurements from 8 to 30

Page 7 - Table of Contents

724-746-5500 | blackbox.com Chapter 4: Using the Cable Length MeterPage 13Table 4-1. AWG/mm/mm2 cross-reference data. AWG Diameter (mm) Area (m

Page 8

724-746-5500 | blackbox.com Cable Length MeterPage 144.2 Pair SGL KeyThe Cable Length Meter can measure single- or two-conductor wires. Press the

Page 9 - Chapter 1: Specifications

724-746-5500 | blackbox.com Page 15Chapter 4: Using the Cable Length Meter3. Press the SET LEN (LEN = Length) key, and the Set Length screen (Fi

Page 10 - Cable Length Meter

724-746-5500 | blackbox.com Page 16Cable Length Meter4.3 Coax, Network, and Telco ModesCoax, Network, and Telco modes detect the distance to opens

Page 11 - Chapter 2: Overview

724-746-5500 | blackbox.com Page 17Chapter 4: Using the Cable Length MeterExample: The factory default for Network wire is .0273 ohms per feet.

Page 13 - Chapter 3: General Functions

724-746-5500 | blackbox.com Page 18Cable Length MeterChanging Opens/Capacitance Coefficient Using Set LengthTo change capacitance coefficients, fo

Page 14

724-746-5500 | blackbox.com Page 19Chapter 4: Using the Cable Length Meter4. Warble tones, low tone for 365 ms, followed by 65 ms of high tone.Fi

Page 15

724-746-5500 | blackbox.com Page 20Cable Length MeterTest Clips8–14 AWG Bus WireTest ClipsFigure 4-7. Wire under test.NOTE: Make sure the wire su

Page 16

724-746-5500 | blackbox.com Page 21Chapter 5: Installing the Battery5. Installing the BatteryBatteries are not included. Use only an alkaline 9-v

Page 17

724-746-5500 | blackbox.com Page 22Cable Length Meter6. Troubleshooting6.1 Calling Black BoxIf you determine that your Cable Length Meter is malfu

Page 18

724-746-5500 | blackbox.com Page 23NOTES

Page 19

724-746-5500 | blackbox.com Page 24NOTES

Page 20

724-746-5500 | blackbox.com Page 25NOTES

Page 21 - 4.5 Calibrating the Test Lead

About Black BoxBlack Box Network Services is your source for more than 118,000 networking and infrastructure products. You’ll find everything from ca

Page 22

724-746-5500 | blackbox.com FCC and IC RFI StatementsPage 1FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STA

Page 23 - 5. Installing the Battery

724-746-5500 | blackbox.com Cable Length MeterPage 2Normas Oficiales Mexicanas (NOM)Electrical Safety StatementINSTRUCCIONES DE SEGURIDAD 1. Tod

Page 24

724-746-5500 | blackbox.com NOM StatementPage 3 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo n

Page 25

Cable Length MeterPage 4724-746-5500 | blackbox.com Trademarks Used in This ManualBlack Box and the Double Diamond logo are registered trademarks

Page 26

724-746-5500 | blackbox.com Table of ContentsPage 5Chapter Page1. Specifications ...

Page 27

724-746-5500 | blackbox.com Cable Length MeterPage 61. SpecificationsCable Types: Single or dual conductor, 8–30 AWG, network, coax, and telcoTemp

Page 28

724-746-5500 | blackbox.com Chapter 1: SpecificationsPage 7Table 1-2. Length measurement range DC (resistance 0–635 ohms). AWG Min. (ft.) Leng

Commentaires sur ces manuels

Pas de commentaire