Black Box CAT5/5e/6 Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Testeurs de réseaux câblés Black Box CAT5/5e/6. Black Box CAT5/5e/6 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 84
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Chapter
Order toll-free in the U.S.: Call 877-877-BBOX (outside
U.S. call 724-746-5500) FREE technical support 24
hours a day, 7 days a week: Call 724-746-5500 or fax
724-746-0746 Mailing address: Black Box Corporation,
1000 Park Drive, Lawrence, PA 15055-1018 Web site:
www.blackbox.
com • E-mail: [email protected]
Customer
Support
Information
BL A C K B O X
®
Digitally certify cables and devices
in Gigabit Etthernet networks.
CAT5/5e/6 LAN Performance Verifier
TS580A-R4
Vue de la page 0
1 2 3 4 5 6 ... 83 84

Résumé du contenu

Page 1 - BL A C K B O X

ChapterOrder toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724

Page 2 - FCC and IC RFI Statements

724-746-5500 | blackbox.com Page 10Chapter 2: Overview• Enables you to test in-line between two devices to determine the autonegotiated speed.•

Page 3 - NOM Statement

724-746-5500 | blackbox.com Page 11Chapter 2: OverviewHelp with device installation and PoE: Installers of VoIP phones, IP cameras, or access p

Page 4

724-746-5500 | blackbox.com Page 12Chapter 2: OverviewWhat is LAN Performance Verification?LAN performance verification means that a UTP cable pas

Page 5

724-746-5500 | blackbox.com Page 13Chapter 2: Overview2.5 The LPV List of FunctionsUTP CABLES. LAN Performance Verification Level 1 tests:√ Lengt

Page 6

724-746-5500 | blackbox.com Page 14Chapter 2: Overview√ Data signal strength. Single-sided test exercises the suspect hub, switch, or PC and disp

Page 7 - Table of Contents

724-746-5500 | blackbox.com Page 15Chapter 3: The 3 Phases of LAN Installation3. The Three Phases of LAN InstallationThe LPV is designed for the

Page 8 - Chapter 1: Specifications

724-746-5500 | blackbox.com Page 16Chapter 4: Faceplate Description4. Faceplate DescriptionThe CAT5/5e/6 LAN Performance Verifier is illustrated i

Page 9

724-746-5500 | blackbox.com Page 17Chapter 4: Faceplate DescriptionFigure 4-1. LAN Performance Verifier and Remote Probe.

Page 10 - Chapter 2: Overview

724-746-5500 | blackbox.com Page 18Chapter 5: Documenting Test Results5. Documenting Test ResultsThe LAN Performance Verifier includes three ways

Page 11

724-746-5500 | blackbox.com Page 19Chapter 6: Operation6. Operation6.1 Powering On and BacklightingFigure 6-1 shows the tester’s backlight select

Page 12

724-746-5500 | blackbox.com Page 2FCC and IC RFI StatementsFEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STAT

Page 13

724-746-5500 | blackbox.com Page 20Chapter 6: Operation6.2 The Main Unit’s Navigation ButtonTo navigate through the LAN Performance Verifier scree

Page 14

724-746-5500 | blackbox.com Page 21Chapter 6: OperationThis menu shown in Figure 6-4 is the gateway to all the LPV’s tests. Scroll the cursor wit

Page 15

724-746-5500 | blackbox.com Page 22Chapter 6: OperationWhen the Level 1 test is complete, you can choose to continue to Level 2 and use real data

Page 16 - Components

724-746-5500 | blackbox.com Page 23Chapter 6: OperationFigure 6-7. Press the down arrow button q after cable is connected.Follow the instruction

Page 17

724-746-5500 | blackbox.com Page 24Chapter 6: OperationFigure 6-8. Stranded or Solid wire selection screen.The LAN Performance Verifier has the un

Page 18 - 5. Documenting Test Results

724-746-5500 | blackbox.com Page 25Chapter 6: OperationFigure 6-9. Testing progress is shown on the screen.Figure 6-10. Any problems will be disp

Page 19 - Chapter 6: Operation

724-746-5500 | blackbox.com Page 26Chapter 6: OperationTime to test: Short cables take longer to test because fewer measurements per pass are poss

Page 20

724-746-5500 | blackbox.com Page 27Chapter 6: OperationFigure 6-12. Remote probe.Figure 6-13. LPV Level 1 final screen (when you see this, Level

Page 21

724-746-5500 | blackbox.com Page 28Chapter 6: OperationFigure 6-14. Test results option screen.REVIEW TEST: View results from the Level 1 test. Af

Page 22

724-746-5500 | blackbox.com Page 29Chapter 6: Operation6.3.3 CAT5/6 UTP LPV Level 2Figure 6-15. Perform LAN Performance Verification Level 2. (UT

Page 23

724-746-5500 | blackbox.com Page 3NOM StatementNormas Oficiales Mexicanas (NOM)Electrical Safety StatementINSTRUCCIONES DE SEGURIDAD1. Todas las

Page 24

724-746-5500 | blackbox.com Page 30Chapter 6: OperationFAQ: What is the difference between Level 1 and Level 2 and when do I use it? Level 1 verif

Page 25

724-746-5500 | blackbox.com Page 31Chapter 6: OperationFirst example (shown in Figure 6-17): The LPV has found a Gigabit device (1000 Mbps) on Pa

Page 26

724-746-5500 | blackbox.com Page 32Chapter 6: OperationFigure 6-20. Review, create a name for the test and/or save the test results.6.3.4 Reviewi

Page 27

724-746-5500 | blackbox.com Page 33Chapter 6: OperationFigure 6-22. Cable Category is the first screen of many that are stored.The “cable catego

Page 28

724-746-5500 | blackbox.com Page 34Chapter 6: OperationLAN Performance Verification Level 1 displays the projected speed capability of the cable.

Page 29

724-746-5500 | blackbox.com Page 35Chapter 6: OperationFigure 6-25. LPV Level 1 Pass/Fail Summary Screen.DELAY OK: The propagation delay of the c

Page 30

724-746-5500 | blackbox.com Page 36Chapter 6: OperationIf tolerance is below 15%, you may wish to consider using a repeater, hub, or switch to sho

Page 31

724-746-5500 | blackbox.com Page 37Chapter 6: OperationFigure 6-28. Propagation and skew per pair.Timing data per pair: The next two screens give

Page 32

724-746-5500 | blackbox.com Page 38Chapter 6: OperationFigure 6-30. Signal levels of real live data from a 100-Mbps switch.The signal level scree

Page 33

724-746-5500 | blackbox.com Page 39Chapter 6: OperationLAN Performance Verification Level 2 displays the LAN Performance Verified Level 2 speed c

Page 34

724-746-5500 | blackbox.com Page 4NOM Statement9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La co

Page 35

724-746-5500 | blackbox.com Page 40Chapter 6: OperationFigure 6-33. Test results option screen “EXIT.“See Section 6.4 for Saving and Naming instru

Page 36

724-746-5500 | blackbox.com Page 41Chapter 6: OperationFigure 6-35. UTP Cable Test Main menu.BASIC TEST UTP: Move the cursor to BASIC TEST and pr

Page 37

724-746-5500 | blackbox.com Page 42Chapter 6: OperationNOTE: If the far end of the cable is connected to any device it will notify you to check t

Page 38

724-746-5500 | blackbox.com Page 43Chapter 6: OperationFigure 6-38. UTP pairs and length are displayed. Select MAP + TRACE for wiremap and tones

Page 39

724-746-5500 | blackbox.com Page 44Chapter 6: OperationFigure 6-40. A correct wire map for a straight through UTP cable.UTP WIRE MAP: The wire ma

Page 40

724-746-5500 | blackbox.com Page 45Chapter 6: OperationFigure 6-42. Select COAX CABLE from Main Menu.COAX CABLE TESTING: Move the cursor to coax

Page 41

724-746-5500 | blackbox.com Page 46Chapter 6: OperationFigure 6-44. Connect the coax cable to the F connector on the Main Unit and select coax. Th

Page 42

724-746-5500 | blackbox.com Page 47Chapter 6: OperationIf the COAX CABLE TEST concludes with a wire map display and no reported errors, the cable

Page 43

724-746-5500 | blackbox.com Page 48Chapter 6: OperationEXIT: Discards the test results and returns to the Main Menu.Figure 6-48. Select EDIT TEST

Page 44

724-746-5500 | blackbox.com Page 49Chapter 6: OperationFor the purposes of learning the naming routine, select START FRESH and follow the exercis

Page 45

724-746-5500 | blackbox.com Page 5NOM Statement18. Servicio por personal calificado deberá ser provisto cuando: A: El cable de poder o el contac

Page 46

724-746-5500 | blackbox.com Page 50Chapter 6: OperationThe UP and DOWN arrows rotate the “LETTERLOOP” to the right and left. The SEL key copies th

Page 47

724-746-5500 | blackbox.com Page 51Chapter 6: OperationSpecial characters in the LETTER LOOP:t Backspace over letters without erasing them.u Forw

Page 48

724-746-5500 | blackbox.com Page 52Chapter 6: OperationFigure 6-53. To review or erase stored readings, select PRINTER MEMORY from the Main Menu.P

Page 49

724-746-5500 | blackbox.com Page 53Chapter 6: OperationREVIEW: Use the UP and DOWN arrow to find the reading you wish to review in Printer Memory

Page 50

724-746-5500 | blackbox.com Page 54Chapter 6: Operation6.6 Printing from a PCTransfer the test readings from the Main Unit to the PC using the sup

Page 51

724-746-5500 | blackbox.com Page 55Chapter 6: Operation4. Save the file using Excel's File>"Save as". See the Readme.doc file

Page 52

724-746-5500 | blackbox.com Page 56Chapter 6: OperationFigure 6-60. Import Report screen.5. Import Report: The LPV spreadsheet’s first step is to

Page 53

724-746-5500 | blackbox.com Page 57Chapter 6: Operation8. After the readings are downloaded, press the “Edit Report” button to launch the sprea

Page 54

724-746-5500 | blackbox.com Page 58Chapter 6: OperationFigure 6-63. LPV.XLS spreadsheet.Typical LPV printoutNOTE: If Level 2 testing was not perf

Page 55

724-746-5500 | blackbox.com Page 59Chapter 6: OperationFigure 6-64. Sample LPV printout.

Page 56

724-746-5500 | blackbox.com Page 6Trademarks Used in this ManualTrademarks Used in this ManualBlack Box and the Double Diamond logo are registered

Page 57

724-746-5500 | blackbox.com Page 60Chapter 6: Operation6.7 Network TestingDisplay the advertised and negotiated speeds of LAN devices and view the

Page 58

724-746-5500 | blackbox.com Page 61Chapter 6: OperationNETWORK PORTS (USE RIGHT JACK): Select Network Ports to display the capabilities of a LAN

Page 59

724-746-5500 | blackbox.com Page 62Chapter 6: OperationSCAN ONE PORT: Move the cursor to SCAN ONE PORT and press SELECT if you wish to display the

Page 60

724-746-5500 | blackbox.com Page 63Chapter 6: OperationFirst example (previous page): The LPV has found a Gigabit device (1000 Mbps) on Pairs 1,

Page 61

724-746-5500 | blackbox.com Page 64Chapter 6: OperationThe signal level screen is a powerful tool. It is a live signal attenuation display. If th

Page 62

724-746-5500 | blackbox.com Page 65Chapter 6: Operation6.7.2 Monitor InlineMove the cursor to MONITOR INLINE and press SELECT if you wish to view

Page 63

724-746-5500 | blackbox.com Page 66Chapter 6: OperationFigure 6-76. Plug in two ports screen.CAPABILITY SCREEN. This screen (or similar) appears a

Page 64

724-746-5500 | blackbox.com Page 67Chapter 6: OperationThe monitor inline test is complete. Data can be transmitted between the two LAN devices w

Page 65

724-746-5500 | blackbox.com Page 68Chapter 6: OperationFigure 6-80. Scroll down and select Send Beacon.Figure 6-81. Port beacon example.PORT BEACO

Page 66

724-746-5500 | blackbox.com Page 69Appendix A: Straight-Through CouplerAppendix A. Straight-Through CouplerWhen installing or troubleshooting a L

Page 67

724-746-5500 | blackbox.com Page 7Table of ContentsTable of Contents1. Specifications ...

Page 68

724-746-5500 | blackbox.com Page 70Appendix B: Ping and TCP/IP Debugging ToolsAppendix B. Ping and TCP/IP Debugging ToolsWhat is TCP/IP: TCP/IP is

Page 69

724-746-5500 | blackbox.com Page 71Appendix B: Ping and TCP/IP Debugging ToolsBecause TCP/IP is so common, Windows® and many UNIX® systems have b

Page 70

724-746-5500 | blackbox.com Page 72Appendix B: Ping and TCP/IP Debugging Tools#2: You are having a problem with one of your workstations communi

Page 71

724-746-5500 | blackbox.com Page 73Appendix B: Ping and TCP/IP Debugging ToolsPing notes: If you want to ping another workstation or server and y

Page 72

724-746-5500 | blackbox.com Page 74Appendix B: Ping and TCP/IP Debugging ToolsExecuting troubleshooting programs from the command line:All the pro

Page 73

724-746-5500 | blackbox.com Page 75Appendix C: Examples of UTP Cable FaultsAppendix C. Examples of UTP Cable FaultsA good cable: A cable that pas

Page 74

724-746-5500 | blackbox.com Page 76Appendix C: Examples of UTP Cable FaultsThe screen shows a 330-foot cable with split pairs at 154 feet. If the

Page 75

724-746-5500 | blackbox.com Page 77Appendix C: Examples of UTP Cable FaultsOpens in cable pairs generate errors in both in skew tests and in wire

Page 76

724-746-5500 | blackbox.com Page 78Appendix C: Examples of UTP Cable FaultsDuring the wire map test, you probably noticed that the indica-tor ligh

Page 77

724-746-5500 | blackbox.com Page 79Appendix D: Making a Correct UTP CableAppendix D. Making a Correct UTP CableTwisted-Pair Cables: Unshielded tw

Page 78

724-746-5500 | blackbox.com Page 8Chapter 1: Specifications1. SpecificationsPower — (2) 9-V batteries (one for test unit and one for probe)Size —

Page 79

724-746-5500 | blackbox.com Page 80Appendix D: Making a Correct UTP Cable• Use good-quality connectors and tools.RJ-45 Connectors (sockets and plu

Page 80

724-746-5500 | blackbox.com Page 81NOTES

Page 81

724-746-5500 | blackbox.com Page 82NOTES

Page 82

724-746-5500 | blackbox.com Page 83NOTES

Page 83

ChapterPage 900About Black BoxBlack Box provides an extensive range of networking and infrastructure products. You’ll find everything from cabinets a

Page 84

724-746-5500 | blackbox.com Page 9Chapter 2: Overview2. Overview2.1 IntroductionOver half of all network problems are caused by faulty cables. An

Commentaires sur ces manuels

Pas de commentaire