Shaft
Conduit O-Rings Pilot Spool Valve Cv
Override
Regional Certs
S 1/4" DD
304 SS
(D-Series only)
N NAMUR
304 SS
L
1” Extended
Linear Shaft
(TXP/TXS w/ Visual
Display F only)
R 1/4” DD 316 SS
(Shaft & external
hardware)
(D-Series Only)
M NAMUR
316 stainless steel
(Shaft & external
hardware)
(D-Series Only)
DXP/DXS
E
(
2) 3/4" NPT
4
(
2) 3/4" NPT
(2) 1/2" NPT
M
(
2) M20
3 (4) M20
6
(
4) 3/4" NPT
D
XR
(Stainless
Co
nduit Entries)
P (2) 1/2” NPT
E
(
2) 3/4” NPT
M (2) M20
D
XR
(Resin Conduit Entries)
A
(
2) 1/2" NPT
B
(
2) 3/4" NPT
C (
2) M20
T
S
E
RIES
TXP/TXS
P
(
2) 1/2” NPT
M (2) M20
E
(
2) 3/4” NPT
(N/A with Pilot Valve)
3
(
4) M20
(N/A with Pilot Valve)
4 (2) 3/4” NPT
(
2) 1/2” NPT
(N/A with Pilot Valve)
TVA
A
(
2) 1/2” NPT
Resin
(TVA only)
C
(
2) M20
Resin
(TVA only)
D SERIES
B
B
u
na-N
E
E
PDM
S S
ilicone
V
V
iton
T S
E
RIES
M
Bu
na/EPDM
mix
(TVA)
Silicone
(TXP/TXS)
Blank
N
o pilot
devices
1 (1) 24Vdc
pilot, .5W,
fail open/
closed
2
(
2) 24Vdc
pilot, .5W, fail
last position
(D Series Only)
4
(
1) 220vac
pilot, 1.9W
fail open/
closed
5
(
1) 220vac
pilot, 1.9W
fail last position
(D Series Only)
7 (
1) 110vac
pilot, 1.1W
fail open/
closed
8 (
2) 110vac
p
ilot, 1.1W
fail last position
(D Series Only)
P
(
1) piezo
pilot, fail open/
closed
(FF only)
(D Series only)
R
(
2) piezo
pilots, fail last
position
(FF only)
(D Series only)
Blank
N
o spool valve
A
A
luminum
hard coat
a
nodized
S
3
04 SS
(D Series Only)
6 316 SS
Blank
N
o spool valve
1
1
.0
Cv
(1/4" NPT Ports)
(T Series Only)
2 1.2 Cv
(1/4" NPT ports)
(D Series Only)
3 3.0 Cv
(D Series Only)
(1/2” NPT ports)
C
C
o
ld Temp
valve
1.0
Cv
(1/4” NPT Ports)
(D-Series Only)
(Sensors L2 and Z2,
Pilot must be 1 or 2;
Sensor FF, Pilot must
be P or R)(O-Ring E
or S only; Spool
Valve S or 6 only)
Bus/sensor L
or Z = -50º
C
B
u
s/sensor FF
= -30º
C
8
1.0
Cv
(1/4” BSP Ports)
(T-Series Only)
(All manual override options
EXCEPT Option 1 are for
D Series only)
Blank
No override
1
S
ingle Pushbutton
Momentary/Latching
2
D
ual Pushbutton
Momentary/Latching
3
S
ingle Pushbutton
Momentary
4 Dual Pushbutton
Momentary
5
M
anual Reset
No voltage release
latching with
pushbutton
(Consult factory if used
with ES sensor option)
(Spool valve must be 6)
A Single palm
actuator
Momentary/Latching
B Dual palm
actuator
Momentary/Latching
C Single palm
actuator
Momentary
D Dual palm
actuator
Momentary
E Manual Reset
No voltage release
latching with palm
actuator
(Consult factory if used
with ES sensor option)
(Spool valve must be 6)
T Partial stroke test
button with lockable
cover
(Sensor ES only)
(Not avail w/ Area Class C)
(DXP/S - Conduit Entries 4 or
3 only. DXR - consult factory)
Blank
No Regional
Ce
rt
B
I
nMetro
(DXP/S only)
N NEPSI
R
G
OST
(Cannot be DXR or TVA)
F FISCO
(D-Series Only)
(Bus/Sensor must be FF;
Area Class must be 0)
K KOSHA
Shaft Conduit
O-Rings
Pilot
Spool Valve Cv Override Regional Certs
Ordering Examples:
DXP-FF0GNEBPA2
DXP-L21GNEB1A2
TXP-M21GNPB1A1
Choose one option from each category to build a complete model number.
TopWorx preferred options.