Status Registers
Modem 3600 10-17
V.42 Compression Control S56
Bit Mapped S57
Inactivity Timer S58
The S58 register specifies the number of minutes the modem waits
before terminating a call when no data is sent or received. This register
is active when in error control mode. 0 disables timer. Issue the \Tn
command to load inactivity timer, n=0-255 minutes.
Bit Value Command Description
1, 0 00
01
10
11
%C
%C2
%C3
%C1
Compression disabled
Compression enabled on transmit data
only
Compression enabled on receive data
only
Compression enabled on transmit and
receive data
7-2 -- -- Reserved
Bit Value Command Description
0 0
1
*RC
*RC1
Standard number codes
15 - 4800 bps
18 - 9600 bps
Alternate number codes
11 - 4800 bps
12 - 9600 bps
4-1 -- -- Reserved
5 0
1
Busy out disabled
Busy out enabled during LAL test mode
(for private PBX use only)
7, 6 -- -- Reserved
Bit Value Command Description
7-0 0
1-255
\T
\Tn (n=1-
255)
Disable
Timer value in minutes
Vue de la page 160