Black Box PCW22A-R3 Manuel d'utilisateur Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 33
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
CHAPTER 4: Operation
19
Data Flow — A/S-2G to Synchronous Device
Bisynchronous Device A/S-2G Converter Asynchronous Device
ACK 1
NAK
Negative Acknowledgment
AA AA 32 32 32 32 3D FF FF
ACK 0
WAK
AA AA 32 32 32 32 6B FF FF
Holds up transmission while
buffer clears DC3 (ASCII 13
Hex) or drop DTR CTS or
user-specified lead
Frees up buffer space.
(Echo CR LF)
Allow resumption of
transmission DC1 (ASCII 11
Hex) or raise DTR
Complete block D
Send block E
(Echo all but CR LF)
X-OFF
Send block C
X-ON
Send block D
Resend block D
Send block E
If A/S-2G buffer is nearly full when asynchronous device is transmitting:
If synchronous device has WAK capability and buffer is full:
2-second interval
If data not properly received by synchronous device or
synchronous device has no WAK capability and buffer is full:
Vue de la page 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 32 33

Commentaires sur ces manuels

Pas de commentaire