ISC Communications
150 —
revision 1
4. Telnet to the assigned IP address and port 1, this should fail quickly (2-3 seconds). This will force
CoBox Micro 100 to take the new assign IP address temporary.
i.e.) TELNET 192.168.2.203 1
5. You now need to Telnet into the IP address to complete the rest of the device configuration.
i.e.) TELNET 192.168.2.203 9999
The CoBox Micro 100 will not save this learned IP address permanently; this procedure is intended as a
temporary measure to allow an administrator to Telnet into the CoBox Micro 100 for configuration. Steps 4
and 5 have to be preformed quickly after each other.
30.4.1 Configuring a CoBox Micro 100 using Telnet
The Cobox Micro 100 can be configured via Telnet or Lantronix's DeviceInstaller. The recommended
method for configuration is Telnet. For more information about using DeviceInstaller, refer to the
manufacturer documentation.
From the command prompt, type the following to enter the CoBox Micro 100 configuration menu:
telnet <IP Address> 9999
This command will open the IP Address using port 9999, which is reserved for configuration. Once the port
is open, choose option 0 for Server configuration.
Once you are in the server configuration, you can set up the IP address, default gateway, and subnet mask to
match your specific network configuration.
You will also need to enter a configuration password for the device. The password can be a maximum of 4
characters only, unless enhanced password is enabled. For more information, refer to the CoBox Micro 100
documentation.
Note: Lenel recommends that you increase the security by enabling enhanced passwords. This allows
for a maximum of 16 characters in the password.
After the Server configuration is complete, choose option 1 for Channel 1 configuration. Make the
following changes in the configuration menu:
a. Baud rate = 38400
b. I/F mode = 4C. See Common I/F Mode Valueson page 176.
c. Flow Control = 02. See
Common Flow Control Valueson page 176.
d. Port Number = 3001
e. Connection Mode = C0
f. Send ‘+++’ in Modem Mode = Y
g. Auto Increment Source Port = N
h. Remote IP Address = (000). (000). (000). (000)
i. Remote Port = 00000
j. DisConnMode = 00
k. Flush Mode = 00
l. Disconnect Time = 00:00
m. Send Char 1 = 00